1 / 3
| Furnace type | Horizontal signal room |
| Effective size of inner liner | 1000x1100x2200mm (W)x(H)x(L) |
| Extended Size Option | 1200x1200x2600mm (W)x(H)x(L) Note: Rated furnace capacity 10000KG, Power 180KW, vacuum unit: 2X+70 pumps + 150 Roots pumps. |
| Max loading capacity | 5000kg |
| Maximum furnace temperature | 950℃ (Suitable for 800℃-850℃ material processes) |
| Limit vacuity | 100Pa |
| Pressure rising rate | < 50Pa/h |
| Air exhausting time | 30min (Vacuum 400Mpa) |
| Heating power | 120kW (3×40kW) |
| Temperature uniformity | ≤ ±2℃ (Insulation) |
| Temperature of furnace surface | Room temperature + 35℃ |
| Temperature Points | 3 |
| Temperature control method | Automatic by program |
| Operation mode | Manual (Furnace door) |
| Cooling water capacity | 10-12 Tons per hour |