Wholesale Oil-Immersed Cooling Transformer for Industrial Use Manufacturers, Service

This Oil-Immersed Transformer is a reliable power transmission device leveraging oil-immersed cooling technology. It enables efficient heat dissipation, enhancing insulation performance and ensuring stable operation even under high loads or harsh conditions.

Featuring high temperature resistance, low operational loss, and long service life, it meets industrial and power grid standards. Ideal for high-voltage power distribution, factories, and large-scale infrastructure, it delivers consistent power while withstanding voltage fluctuations, supporting safe and energy-efficient electricity supply.

Product Description

Product Specification

Basic Information

Item Specification
Product Model Example: S11-M-500/10, S13-R-1000/20, S15-H-2500/35 (S=Three-Phase; 11/13/15=Efficiency Class; M/R/H=Structural Type; Capacity kVA/HV kV)
Rated Capacity 30kVA~5000kVA (ONAN: 100% rated capacity; ODAF: 130%; ODWF: 160%)
Phase/Frequency Three-Phase (standard); 50Hz/60Hz (±1% tolerance, customizable for 400Hz special use)
Connection Group Dyn11 (default for distribution), Yd11 (for power transformer); Yyn0 (optional)
Cooling Type ONAN (Oil Natural Air Natural) / ODAF (Oil Directed Air Forced) / ODWF (Oil Directed Water Forced)

Operating & Environmental Conditions

Ambient Temperature -25℃~40℃ (standard); -40℃~45℃ (low-temperature/high-temperature models with modified oil).
Altitude ≤1000m (derate 5% at 1500m, 10% at 3000m, 15% at 4000m).
Humidity ≤90% @25℃ (no condensation); ≤50% @40℃.
Seismic Resistance GB 50260-2013 / IEC 60076-11, 7-degree intensity (0.15g acceleration); 8-degree optional.
Protection Class IP23 (outdoor, dust/rainproof) / IP20 (indoor).

Losses & Impedance (Typical Values)

Efficiency Class Parameter 500kVA/10kV Example Test Condition
S11 (IEC IE1) No-Load Loss (Po) ≤810W Rated voltage/frequency
S11 (IEC IE1) Load Loss (Pk) ≤5200W Rated current, 75℃
S13 (IEC IE2) No-Load Loss (Po) ≤650W (20% lower than S11) Rated voltage/frequency
S15 (IEC IE3) No-Load Loss (Po) ≤520W (36% lower than S11) Rated voltage/frequency
All Classes Short-Circuit Impedance 4%~6% (10kV); 6%~8% (35kV) 75℃, ±10% tolerance

Efficiency Compliance: GB 20052-2024 Class 2 (S11/S13) / Class 1 (S15); IEC 60076-11 IE1/IE2/IE3. Customizable for special voltages and high-altitude requirements.

Product Advantages

1. Superior Heat Dissipation Efficiency Leveraging the high thermal conductivity of insulating oil, the transformer efficiently transfers internal heat to the tank and radiators, ensuring stable operation under high loads.
2. Excellent Insulation Performance Insulating oil isolates air, moisture, and dust, significantly reducing the risk of leakage or short circuits in humid or harsh industrial environments.
3. Strong Overload Capacity The optimized oil-immersed structure allows it to withstand short-term power surges without performance degradation, avoiding unexpected shutdowns.
4. Long Service Life With a sealed tank design protecting internal components from corrosion and wear, the transformer’s design life typically exceeds 20 years.
5. Low Maintenance Requirements The sealed structure minimizes the need for internal cleaning. Periodic checks of oil levels and tank tightness are generally sufficient for long-term operation.
6. Suitable for High-Voltage Scenarios Meets strict voltage resistance standards, making it ideal for high-voltage power grids, large industrial plants, and substations.

Product Display

Application Scenarios

Power Systems

Indispensable for voltage conversion in high-voltage transmission networks (110kV-500kV), substation transformation, and urban/rural distribution networks.

Industrial Sector

Powers heavy machinery in steel mills and chemical plants. It also acts as a step-up transformer for solar and wind power plants, integrating new energy into the grid.

Infrastructure & Buildings

Reliable power for hospitals, data centers, airports, and transportation hubs (high-speed rail and subways) where 24/7 stable supply is critical.

Harsh Environments

The robust sealed design is perfect for humid mines, remote oilfields, and off-grid mountainous villages where maintenance access is limited.

Frequently Asked Questions

What is the expected service life of these transformers?
The design life typically exceeds 20 years due to the sealed oil tank which protects internal components from corrosion and wear.
How does the transformer handle extreme temperatures?
Standard models operate between -25°C to 40°C. For extreme conditions, we offer modified oil models capable of handling -40°C to 45°C.
What are the available cooling methods?
We support ONAN (Oil Natural Air Natural), ODAF (Oil Directed Air Forced), and ODWF (Oil Directed Water Forced) cooling types.
Are these transformers suitable for high-altitude use?
Yes. While the standard is ≤1000m, they can be derated for altitudes up to 4000m or customized for specific high-altitude requirements.
What efficiency standards do they comply with?
They comply with GB 20052-2024 (Class 1/2) and international IEC 60076-11 IE1, IE2, and IE3 efficiency standards.
What maintenance is required?
Maintenance is low. It primarily involves periodic checks of the oil level, oil quality, and the tightness of the sealed tank.